Mc11 head wall metal flashing.
Roof rake flashing detail.
Gable rake flashing is a professional trim product that covers the exposed ends of metal roofing panels resulting in a neater appearance.
Copper locking strips of the same weight as the flashing are soldered to the pans between seams at least 6 from the wall and engage the base.
Chapter 9 10 wood.
Two ways to flash roof edges.
Past the outside corner.
Metal flashing option built up roof detail eave figure 9 7.
The rake is not exactly on the roof.
Hold a piece of rake flashing in place and then mark and cut its leading edge plumb to the eave fascia.
It is a term that describes the sloped sides of a gable end.
Mc12a pan flashing roof to sidewall 2.
Galvanized steel is a trusted low maintenance product that is known for durability.
Hold the eave flashing in place running about 1 in.
Detailing for performance exterior built up roof detail rake at wall figure 9 8.
Roofing terminology may be difficult to understand unless you are a builder or roofer.
To emphasize the importance of proper roof and deck flashing and to provide typical and enhanced flashing techniques for coastal homes.
Click to enlarge any image.
The detail shows the method of flashing the head of a standing seam shed roof.
One common method is to lay the edge metal under the eaves membrane and over the rake.
See fact sheet nos.
2 350 x 3 4 with hem features safety edge 015 material thickness.
7 2 and 7 3 for rake and eave details.
Protect the eave from ice dams and sideways rain step one in steep slope roofing is the edge flashing.
Mc12b metal flashing options.
Without gable rake flashing protection wind driven rain can begin to rot the fascia and roof deck.
Terms are used to break down the various areas of a roof and a rake is one of many roof sections.
Cut the top of the flashing at a slight angle to the face of the rake and bend the vertical leg back against the rake trim.
Roof drip edge flashing serves multiple functions on a building the foremost of which is to assist water in leaving the roof edge with minimum damage to other building components by directing the water off of the roof and into the gutter.
Mc10c low slope ventilated eave detail.
Mc12 pan flashing roof to sidewall.
The standing seams are laid flat 8 from the vertical wall folded 3 4 and secured with copper cleats spaced 12 o c.
Gable rake flashing gable and rake flashings are used on two slope roofs with a center peak to protect the roof wood and help provide a barrier that prevents water from penetrating the roof.