Minimum thickness most roofs will be sheathed in plywood at least 3 8 inch thick.
Roof sheathing thickness ohio.
Where flashing is of metal the metal shall be corrosion resistant with a thickness of not less than 0 019 inch 0 483 mm no.
Wall and roof intersections at gutters wherever there is a change in roof slope or direction and around roof openings.
Loads will vary with the.
I was told that the spring of 2008 it changed.
Underlayment shall be applied in accordance with section 1507 2 8 except all laps shall be a minimum of 4 inches 102 mm.
This minimum will only work if the rafters are set 16 inches apart at most and if the roof doesn t have too much load.
Installation details shall conform to sections 2304 7 1 and 2304 7 2 for floor and roof sheathing respectively.
Does anyone know what is the current ohio residential code is for roof decking.
Sheathing should be a minimum of 19 32 inch thick.
Rafters shall be nailed to the top wall plates in accordance with table 602 3 1 unless the roof assembly is required to comply with the uplift requirements of section 802 11.
The typical thickness range for sheathing is 3 8 to 3 4 inch.
Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of section 2304 7.
1 inch 25 4 mm.
Underlayment shall be attached using metal or plastic cap nails with a head diameter of not less than 1 inch 25 mm with a thickness of at least 32 gage 0 0134 inch 0 34 mm sheet metal.
Roof sheathing thickness unlike with plywood siding the plywood sheet to be used for sheathing should be at least 3 8 inch thick.
This is for a re roof of a shed style roof of a garage with 2x6 rafters not trusses.
Roof sheathing comes in grid marked 4 by 8 foot sheets and should be installed perpendicular to the frame.
Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 9 5 mm head complying with astm f1667 of a length to penetrate through the roofing materials and not less than 3 4 inch 19 1 mm into the roof sheathing.
Where the roof sheathing is less than 3 4 inch 19 1 mm thick the fasteners shall penetrate through the sheathing.
Allowable spans for lumber floor and roof sheathing a b for si.
That will suffice on a roof with rafters set 16 inches apart with minimal roof loads.
That s considered to be the minimum.
8d ring shank nails should be used instead.
I am trying to find out the decking thickness for 24oc.