The minimum design roof snow load.
Roof snow load map ny.
The ground snow loads to be used in determining the design snow loads for roofs shall be determined in accordance with asce.
The north zone design live load equates to 40 pounds per square foot the middle zone equates to 30 pounds per square foot and the south zone equates to 20 pounds per square foot.
This is a beta release of the new atc hazards by location website.
Flat roof snow load p f.
Chapter 16 section 1608 for any location in the state of new york.
By multiplying the gsl by 0 7 or 70 of the ground snow load.
Snow load importance.
Flat roof snow loads of 30 psf 1 44 kn m 2 or less need not be combined with seismic loads.
In areas where the ground snow load p g exceeds 10 pounds per square foot psf 0 479 kn m 2 the following additional information shall also be provided regardless of whether snow loads govern the design of the roof.
In some cases this lo ad may be reduced for a sloped roof to account for sliding snow and improved drainage of meltwater.
Crane hook loads need not be combined with roof live load or with more than three fourths of the snow load or one half of the wind load.
As an example the flat roof snow load for a roof located in a 55 psf snow z one is typically 70 of 55 or 38 5 psf.
Use our new york ground snow loads map to easily determine the ground snow load 2010 building code of new york state.
A great deal of confusion currently exists among engineers architects recreation specialists and maintenance personnel concerning the proper snow loading to use for the design and maintenance of trail bridges building roofs and other structures in mountainous high snow load areas.
The north zone middle zone and the south zone are identified on the roof load zone map above.
In areas of the state outside of certified local government jurisdictions the design snow load shall be based on the ground snow loads developed in snow loads for structural design in montana authored by f f.
Please contact us with feedback.
Why snow load information.
Snow exposure factor c e.
However for roofs having a non slippery.
New york the state has amended the snow load requirements of the ibc chapter 16 with the 2010 building code of new york state which states that the ground snow loads to be used in determining the design snow loads for roofs shall be determined in accordance with asce 7 or figure 1608 2.
You can click on the map below to find the design ground snow load for that location.
The ground snow load p g shall be indicated.
Schilke civil agricultural engineering montana state university august 1989.