This guidance page gives you a broad view of the requirements for using the roof space in dwellings and if more detailed information is required it is necessary to refer to the technical handbook and the building standards scotland regulations.
Roof ventilation requirements scotland.
You can calculate attic ventilation requirements by determining the square footage of your attic.
In this case ventilation is required and the roof can still become wet with condensation which may cause materials to decay.
3 14 ventilation 3 14 functional standard 3 14 0 introduction 3 14 1 ventilation generally 3 14 2 ventilation of dwellings 3 14 3 ventilation of conservatories 3 14 4 ventilation of areas designated for drying of washing 3 14 5 trickle ventilators 3 14 6 passive stack ventilation systems 3 14 7 conservatories and extensions built over existing windows 3 14 8 mechanical.
As modern construction techniques continue to place more emphasis on energy conservation minimising the heat loss from buildings insulation thicknesses have increased and air tightness is constantly improving.
A ridge vent is a ventilation strip that is placed along the ridgeline of the home.
It is important that air movement occurs and is not impeded by any framing members of the.
Select 100 is a classically styled bathroom extractor fan range designed to comply with current building regulations.
We publish technical handbooks which explain how to achieve the requirements set out in the building scotland regulations 2004 we regularly consult with industry to review our guidance.
Prior to installing the ridge vent a 1 inch wide strip of roof decking is cut out along both sides of the ridgeline to allow for air movement through the vent.
Why is there a need for roof ventilation.
There are two types of flat roof.
When used in accordance with the certificate swish ventilators will satisfy the following statutory requirements.
A range of options and models are available including pull cord timer humidistat remote switch and selv extra low voltage.
A new standard bs 8612 was released in february 2018 and sets out minimum performance requirements for dry fixed roofing systems in regards to fixing wind load resistance durability and ventilation according to bs 5250.
A minimum 50mm free air path should be maintained between the top of the insulation and the underside of the roof decking.
The key to proper ventilation of your roof and attic is balance.
The amount of space you devote to intake must be equal to the amount you allow for exhaust and these must be calculated according to the size of your attic and slope of your roof.
Take a look at the reasons behind roof ventilation the different types and if you need it.
Cold roofs have the waterproof layer placed directly onto the roof deck and the insulation inside the roof just above the ceiling.
Swish ventilators for roof voids are covered by british board of agrément certificate no 91 2620.